Error code
1DFAH
1DFCH
1DFDH
1E30H
1E31H
1E32H
1E33H
1E34H
1E35H
1E36H
1E37H
14 TROUBLESHOOTING
648
14.5 List of Error Codes
Downloaded from
ManualsNet.com
Error name
Error details and causes
Synchronous encoder via
• "[Pr.141] IP address" of the axis No. selected as
servo amplifier invalid error
"Synchronous encoder via servo amplifier" in
"[Pr.320] Synchronous encoder axis type" is not set
or it is set as the virtual servo amplifier axis.
• The servo amplifier axis set as synchronous encoder
via servo amplifier is not supported with scale
measurement mode.
• The servo amplifier axis set as synchronous encoder
via servo amplifier is connected to the linear scale.
[Operation status at error occurrence]
The READY signal [X0] is not turned ON.
Command generation axis
An attempt was made to start forward run speed
speed-position error
position or reverse run speed/position when "[Pr.346]
Command generation axis length per cycle" is "0".
[Operation status at error occurrence]
The command generation axis does not start.
Outside command generation
A value other than 0 to 2147483647 was input for
axis length per cycle setting
"[Pr.346] Command generation axis length per cycle".
error
[Operation status at error occurrence]
The system operates as "[Pr.346] Command
generation axis length per cycle" is 0.
Outside main input axis No.
• The setting value of the synchronous parameter
range
"[Pr.400] Main input axis No." is outside the setting
range.
• The same servo input axis No. as the output axis
has been set for "[Pr.400] Main input axis No.".
[Operation status at error occurrence]
Synchronous control does not start.
Outside sub input axis No.
• The setting value of the synchronous parameter
range
"[Pr.401] Sub input axis No." is outside the setting
range.
• The same servo input axis No. as the output axis is
set for "[Pr.401] Sub input axis No.".
[Operation status at error occurrence]
Synchronous control does not start.
Outside main shaft gear:
The synchronous parameter "[Pr.404] Main shaft gear:
denominator range
Denominator" is set to 0 or lower.
[Operation status at error occurrence]
Synchronous control does not start.
Main shaft gear operation
Overflow (sign reversion) occurred in input values,
overflow
because the main shaft gear ratio is too large.
[Operation status at error occurrence]
Synchronous control is immediately stopped.
Outside main shaft clutch
The setting value of the synchronous parameter
control setting range
"[Pr.405] Main shaft clutch control setting" is outside
the setting range.
[Operation status at error occurrence]
Synchronous control does not start.
Outside main shaft clutch
The setting value of the synchronous parameter
reference address setting
"[Pr.406] Main shaft clutch reference address setting"
range
is outside the setting range.
[Operation status at error occurrence]
Synchronous control does not start.
Outside main shaft clutch
The setting value of the synchronous parameter
smoothing method range
"[Pr.411] Main shaft clutch smoothing method" is
outside the setting range.
[Operation status at error occurrence]
Synchronous control does not start.
Outside main shaft clutch
The setting value of the synchronous parameter
smoothing time constant
"[Pr.412] Main shaft clutch smoothing time constant" is
range
outside the setting range.
[Operation status at error occurrence]
Synchronous control does not start.
search engine
Remedy
After you solve the problem, switch the power off
and then on, or reset the PLC.
Set a value within the range from 1 to
2147483647 for "[Pr.346] Command generation
axis length per cycle".
Set a value within the range from 0 to
2147483647 for "[Pr.346] Command generation
axis length per cycle".
• Set within the range.
• Do not set up the same servo input axis No.
as the output axis.
• Set within the range.
• Do not set up the same servo input axis No.
as the output axis.
Set a value within the range of 1 to 2147483647.
• Set a smaller absolute value for the
synchronous parameter "[Pr.403] Main shaft
gear: Numerator".
• Set a larger value for the synchronous
parameter "[Pr.404] Main shaft gear:
Denominator".
• Decrease the input axis speed.
Set within the range.
Set within the range.
Set within the range.
Set within the range.