Mitsubishi Electric MELSEC iQ-R Series User Manual page 49

Programmable
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Deceleration stop conditions during continuous path control
Deceleration stops are not carried out in continuous path control, but the machine will carry out a deceleration stop to speed
"0" in the following 3 cases.
• When the operation pattern of the positioning data currently being executed is "continuous path control: 11", and the
movement direction of the positioning data currently being executed differs from that of the next positioning data. (Only for
1-axis positioning control (Refer to the next point.))
V
Positioning data No.1
Operation pattern: 11
Positioning data No.2
Operation pattern: 00
• During operation by step operation. (Page 279 Step function)
• When there is an error in the positioning data to carry out the next operation.
[Positioning by interpolation]
Downloaded from
ManualsNet.com
Speed becomes 0.
• The movement direction is not checked during interpolation operations. Thus, automatic deceleration to a
stop will not be carried out even if the movement direction is changed (See the figures below). Because of
this, the interpolation axis may rapidly reverse direction. To avoid this rapid direction reversal in the
interpolation axis, set the pass point to continuous positioning control "01" instead of setting it to continuous
path control "11".
Positioning
Positioning
data No.1
data No.2
Positioning data No.1 ••• Continuous path control
• When a "0" is set in "[Da.6] Positioning address/movement amount" of the continuous path control
positioning data, the command speed is reduced to 0 in an operation cycle. When a "0" is set in "[Da.6]
Positioning address/movement amount" to increase the number of speed change points in the future,
change "[Da.2] Control method" to the "NOP" to make the control nonexecutable. (Page 132 NOP
instruction)
• In the continuous path control positioning data, assure a movement distance so that the execution time with
that data is 100 ms or longer, or lower the command speed.
search engine
[Reference axis operation]
V
Reference axis
Positioning data No.1
[Interpolation axis operation]
V
Positioning data No.1
Positioning data No.2
Rapid reverse
direction
Positioning data No.2
3 MAJOR POSITIONING CONTROL
3.1 Outline of Major Positioning Controls
3
t
t
47