[Cd.33] Simultaneous starting axis start data No.3
Use this data item to specify a start data No.3 for each axis that starts simultaneously.
For 2 axis simultaneous starting and 3 axis simultaneous starting, the axis setting is not required. (Setting
value is ignored.)
Fetch cycle: At start
■Setting range
• Set with a decimal.
Setting range of [Cd.33]
1 to 600
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".
[Cd.34] Step mode
To perform a step operation, use this data item to specify the units by which the stepping should be performed.
Fetch cycle: At start
■Setting value
• Set with a decimal.
Setting value
0
1
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".
[Cd.35] Step valid flag
This data item validates or invalidates step operations.
Fetch cycle: At start
■Setting value
• Set with a decimal.
Setting value
0
1
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 402 Axis control data
■Default value
Set to "0".