9.4
The "external input signal select function" is used to select from the following signals when using each external input signal of
each axis (upper/lower stroke limit signal (FLS/RLS), proximity dog signal (DOG), and stop signal (STOP)).
• External input signal of servo amplifier
• External input signal via CPU (buffer memory)
Setting details
The method for setting the external input signals used in each axis (upper/lower stroke limit signal (FLS/RLS), proximity dog
signal (DOG), and stop signal (STOP)) is shown below.
Setting item
[Pr.116]
FLS signal selection
[Pr.117]
RLS signal selection
[Pr.118]
DOG signal selection
[Pr.119]
STOP signal
selection
*1 The setting is not available in "[Pr.119] STOP signal selection". If it is set, the error "STOP signal selection error" (error code: 1BD3H)
occurs and the PLC READY signal [Y0] is not turned ON.
- Set "Function selection C-G DI status read selection (PC79.0)" to "Eh".
- Set "Function selection D-4 Sensor input method selection (PD41.3)" to "1: Input from controller".
- Set "Function selection D-4 Limit switch enabled status selection (PD41.2)" to "1: Enabled only for homing
mode".
- Set "DI pin polarity selection (PD60)" to "00000000h".
- Set "Function selection T-3 Device input polarity 1 (PT29.0)" to "1: Dog detection with ON".
If the above servo parameters are set to different values, the error "Servo parameter invalid" (error code:
1DC8H) occurs, and the Motion module rewrites the value of said servo parameters to the above values. The
servo parameters are enabled after the Motion module or servo amplifier is reset.
■When "1: Servo amplifier" is set to the input type
The following table shows the pin No. of the external input signal of the servo amplifier to be used.
Pin No. of servo amplifier
CN3-2
CN3-12
CN3-19
CN3-20
*1 This servo amplifier means about MR-J5(W)-_G_(-RJ). For details, refer to the servo amplifier instruction manual to be used.
For MR-J5(W)-G: MR-J5 User's Manual (Hardware)
Downloaded from
ManualsNet.com

External Input Signal Select Function

Initial value
0001H
0001H
0001H
0002H
• When using the MR-J5(W)-G, set the servo parameters as follows.
• When parameter automatic setting is enabled, the saved parameters are automatically updated. Check the
execution result of automatically updating the saved parameters in the event history.
• When "[Pr.95] External command signal selection" is set to use the DOG signal of the axis, the DOG signal
of the servo amplifier is used regardless of the setting value of "[Pr.118] DOG signal selection". For details of
the logic selection for the signal, refer to the following. Page 658 Devices Compatible with CC-Link IE
TSN
• A virtual servo amplifier cannot be used in an external command. When the axis selected in "[Pr.95]
External command signal selection" is a virtual servo amplifier, the setting is invalid.
*1
search engine
Setting details
■Set with a hexadecimal.
H _ _ _ _
Input type
Set the input type used as the external input signal.
1 (0001H): Servo amplifier
2 (0002H): Buffer memory
15 (000FH): Invalid
Signal name
LSP
LSN
DOG
EM2
*1
9 COMMON FUNCTIONS
9.4 External Input Signal Select Function
9
315