Warning code
(Hexadecimal)
0EB3H
0EB4H

Servo amplifier detection warning

For details of servo amplifier detection warnings, refer to the manual of each servo amplifier.
14 TROUBLESHOOTING
622
14.4 List of Warning Codes
Downloaded from
ManualsNet.com
Warning name
Error details and causes
Outside cam position
"[Cd.617] Cam position calculation: Cam axis current
calculation cam axis current
value per cycle" is outside the range of 0 to "Cam axis
value per cycle range
length per cycle".
[Operation status at warning occurrence]
Cam position calculation is not executed.
Cam position calculation cam
Corresponding cam axis current value per cycle could
axis 1 cycle current value
not be calculated during cam axis current value per
calculation disable
cycle calculation. (Occurs in reciprocated cam pattern)
[Operation status at warning occurrence]
Cam position calculation is not executed.
search engine
Remedy
Set a value within the range of 0 to "Cam axis
length per cycle".
Set "[Cd.614] Cam position calculation: Stroke
amount", "[Cd.616] Cam position calculation:
Cam reference position", and "[Cd.618] Cam
position calculation: Cam axis feed current
value" within the range of reciprocated cam
pattern stroke.