Mark detection function
The following shows the relation between the buffer memory addresses for mark detection function and the various items.
■Mark detection parameters
k: Mark detection setting No. - 1
Item
[Pr.800]
Mark detection signal setting
[Pr.801]
Mark detection signal compensation time
[Pr.802]
Mark detection data type
[Pr.803]
Mark detection data axis No.
[Pr.804]
Mark detection data buffer memory No.
[Pr.805]
Latch data range upper limit value
[Pr.806]
Latch data range lower limit value
[Pr.807]
Mark detection mode setting
[Pr.811]
Mark detection signal detection direction setting
■Mark detection control data
k: Mark detection setting No. - 1
Item
[Cd.800]
Number of mark detection clear request
[Cd.801]
Mark detection invalid flag
[Cd.802]
Latch data range change request
■Mark detection monitor data
k: Mark detection setting No. - 1
Item
[Md.800]
Number of mark detection
[Md.801]
Mark detection data storage area (1 to 32)
12 DATA USED FOR POSITIONING CONTROL
408
12.2 List of Buffer Memory Addresses
Downloaded from
ManualsNet.com
search engine
1
2
3
32
Buffer memory address
Axis 1 to axis 16
54000+20k
54001+20k
54002+20k
54003+20k
54004+20k
54005+20k
54006+20k
54007+20k
54008+20k
54009+20k
54010+20k
54014+20k
Buffer memory address
Axis 1 to axis 16
54640+10k
54641+10k
54642+10k
Buffer memory address
Axis 1 to axis 16
54960+80k
54962+80k
54963+80k
54964+80k
54965+80k
54966+80k
54967+80k
55024+80k
55025+80k