[Pr.91] to [Pr.94] Optional data monitor: Data type setting
Set the index of the CiA402 object of the slave device.
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 400 Extended parameters
[Pr.591] to [Pr.594] Optional data monitor: Data type expansion setting
Set the data type monitored in the optional data monitor function. For details of the data, refer to the manual of servo amplifier.
Set the sub-index and size of the CiA402 object of the slave device.
For MR-J5(W)-G: MR-J5-G/MR-J5W-G User's Manual (Object Dictionary)
Specify the size in bit lengths.
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 400 Extended parameters
12 DATA USED FOR POSITIONING CONTROL
450
12.3 Basic Setting
Downloaded from
ManualsNet.com
• Registered monitor addresses for the optional data monitor are imported after the power is turned ON or the
CPU module is reset.
• Set data types that use 2 points in either "[Pr.91] Optional data monitor: Data type setting 1" and "[Pr.591]
Optional data monitor: Data type expansion setting 1" or "[Pr.93] Optional data monitor: Data type setting 3"
and "[Pr.593] Optional data monitor: Data type expansion setting 3". The setting values of both "[Pr.92]
Optional data monitor: Data type setting 2" and "[Pr.592] Optional data monitor: Data type expansion setting
2" and [Pr.94] Optional data monitor: Data type setting 4" and "[Pr.594] Optional data monitor: Data type
expansion setting 4" are ignored.
• When a value other than 08H, 10H, 20H, or 40H is set as the size in "[Pr.591] Optional data monitor: Data
type expansion setting 1" to "[Pr.594] Optional data monitor: Data type expansion setting 4", the value is
treated as being 20H.
• When a CiA402 object that cannot be monitored is set, the error "PDO mapping setting error" (error code:
1C48H) occurs and communication with that axis is not performed.