[Da.9] Dwell time/JUMP destination positioning data No.
Set the "dwell time" or "positioning data No." corresponding to "[Da.2] Control method".
• When a method other than "JUMP instruction" is set for "[Da.2] Control method": Set the "dwell time".
• When "JUMP instruction" is set for "[Da.2] Control method": Set the "positioning data No." for the JUMP destination.
When the "dwell time" is set, the setting details of the "dwell time" will be as follows according to "[Da.1] Operation pattern".
■When "[Da.1] Operation pattern" in "00: Positioning complete"
• Set the time from when the positioning ends to when the "positioning complete signal" turns ON as the "dwell time".
Positioning complete signal
■When "[Da.1] Operation pattern" is "01: Continuous positioning control"
• Set the time from when positioning control ends to when the next positioning control starts as the "dwell time".
V
Positioning control
■When "[Da.1] Operation pattern" is "11: Continuous path control"
• The setting value is irrelevant to the control. (The "dwell time" is 0 ms.)
V
Positioning control
[Da.2] setting value
JUMP instruction: 82H
Other than JUMP instruction
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 404 Positioning data
Downloaded from
ManualsNet.com
V
Positioning control
OFF
Next positioning control
t
[Da.9]
Dwell time/JUMP destination positioning data No.
Next positioning control
t
No dwell time (0 ms)
Setting item
Positioning data No.
Dwell time
search engine
t
ON
[Da.9]
Dwell time/JUMP destination positioning data No.
Value set with the engineering tool
1 to 600
0 to 65535 (ms)
12 DATA USED FOR POSITIONING CONTROL
Value set with a program
1 to 600
0 to 65535 (ms)
12.4 Positioning data
12
465