The following explains the condition data setting items [Da.15] to [Da.19] and [Da.23] to [Da.26]. (The buffer memory
addresses shown are those of the "condition data No.1 (block No.7000)".)
*1
Block No.
7000
7001
7002
7003
7004
*1 Setting cannot be made when the "Pre-reading start function" is used. If you set any of Nos. 7000 to 7004 and perform the Pre-reading
start function, the error "Outside start No. range" (error code: 1AA3H)" will occur.
Refer to the following for details.
Page 270 Pre-reading start function
Downloaded from
ManualsNet.com
• To perform a high-level positioning control using block start data, set a number between 7000 and 7004 to
"[Cd.3] Positioning start No." and use "[Cd.4] Positioning starting point No." to specify a point No. between 1
and 50, a position counted from the beginning of the block.
• The number between 7000 and 7004 specified here is called the "block No.".
• With the Motion module, up to 50 "block start data" points and up to 10 "condition data" items can be
assigned to each "block No.".
Axis
Block start data
Axis 1
Start block 0
Maximum control
axis No.
Axis 1
Start block 1
Maximum control
axis No.
Axis 1
Start block 2
Maximum control
axis No.
Axis 1
Start block 3
Maximum control
axis No.
Axis 1
Start block 4
Maximum control
axis No.
search engine
Condition
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
12 DATA USED FOR POSITIONING CONTROL
Buffer memory
Engineering
tool
Supports the settings
Supports the
settings
12.6 Condition Data