Example of a start program for high-level positioning control

The following shows an example of a start program for high-level positioning control in which the 1st point "block start data" of
axis 1 is started. (The block No. is regarded as "7000".)
Control data that require setting
The following control data must be set to execute high-level positioning control. The setting is carried out using a program.
n: Axis No. - 1
Setting item
[Cd.3]
Positioning start No.
[Cd.4]
Positioning starting point No.
For details of the setting, refer to the following.
Page 512 Control Data
Start conditions
The following conditions must be fulfilled when starting the control. The required conditions must also be integrated into the
program, and configured so the control does not start unless the conditions are fulfilled.
Signal name
Interface
PLC READY signal
signal
READY signal
All axis servo ON
Synchronization flag
Axis stop signal
Start complete signal
BUSY signal
Error detection signal
M code ON signal
External
Forced stop input signal
signal
Stop signal
Upper limit signal (FLS)
Lower limit signal (RLS)
*1 The BUSY signal, whose axis No. exceeds the number of controlled axes, cannot be used.
4 HIGH-LEVEL POSITIONING CONTROL
154
4.5 Start Program for High-level Positioning Control
Downloaded from
ManualsNet.com
Setting
Setting details
value
7000
Set "7000" to indicate control using "block start data".
1
Set the point No. of the "block start data" to be started.
search engine
Signal state
ON
CPU module preparation completed
ON
Preparation completed
ON
All axis servo ON
ON
The buffer memory can be accessed.
OFF
Axis stop signal is OFF
OFF
Start complete signal is OFF
OFF
BUSY signal is OFF
OFF
There is no error
OFF
M code ON signal is OFF
ON
Forced stop input signal is ON
OFF
Stop signal is OFF
ON
Within limit range
ON
Within limit range
Buffer memory address
Axis 1 to axis 16
4300+100n
4301+100n
Device
Y0
X0
Y1
X1
[Cd.180] Axis stop
[Md.31] Status: b14
*1
X10 to X1F
[Md.31] Status: b13
[Md.31] Status: b12