[Manual pulse generator operation]
"Manual pulse generator operation" is a control method in which positioning is carried out in response to the number of pulses
input from a manual pulse generator (the number of input command is output). This operation is used for manual fine
adjustment, etc., when carrying out accurate positioning to obtain the positioning address.
Motion module
High-speed
counter
module
Pulse input
Manual pulse generator
■Manual control sub functions
Refer to the "Combination of Main Functions and Sub Functions" in the following manual for details on "sub functions" that
can be combined with manual control.
MELSEC iQ-R Motion Module User's Manual (Startup)
Also refer to the following for details on each sub function.
Page 222 CONTROL SUB FUNCTIONS
■Monitoring manual control
Refer to the following for directly monitoring the buffer memory using an engineering tool.
Page 479 Monitor Data
Also refer to "Help" in the "Simple Motion Module Setting Function" when monitoring with the monitor functions of an
engineering tool.
5 MANUAL CONTROL
158
5.1 Outline of Manual Control
Downloaded from
ManualsNet.com
Movement in response to the command pulses
Command
output
M
search engine