Warning code
(Hexadecimal)
0E98H
0E99H
0E9AH
0E9BH
0EA0H
0EA1H
0EA2H
0EA3H
0EA4H
0EA5H
0EA6H
0EB0H
0EB1H
0EB2H
Downloaded from
ManualsNet.com
Warning name
Error details and causes
Cam open area capacity over
• The free area in the cam open area is insufficient
during the cam data writing operation.
• The writable area is insufficient due to the
decoupling of free area.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Coordinate data error
• Input value of coordinate data is a negative value
during the cam data writing operation.
• Input value of coordinate data is not "X
during the cam data writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Cam data reading operation
Cam data reading operation is executed with the cam
inhibit
data read password set.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Cam data writing operation
Cam data writing operation is executed with the cam
inhibit
data write password set.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Outside cam auto-generation
"[Cd.609] Cam auto-generation cam No." is outside the
cam No. range
range of 1 to 256.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Outside cam auto-generation
"[Cd.610] Cam auto-generation type" is other than 1.
type range
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Cam auto-generation cam
• The free area in the cam storage area is insufficient.
storage area capacity over
• The writable area is insufficient due to the
decoupling of free area.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Cam auto-generation cam
• The free area in the cam open area is insufficient.
open area capacity over
• The writable area is insufficient due to the
decoupling of free area.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Outside cam auto-generation
"[Cd.611] Cam auto-generation data" is outside the
value range
setting range.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Cam auto-generation
"[Cd.611] Cam auto-generation data" is set to the value
calculation disable
that the cam pattern cannot be generated. (Such as
when the sheet synchronization width is larger than the
sheet length in the cam for a rotary cutter)
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Cam auto-generation data
Cam auto-generation is executed with the cam data
write inhibit
write password set.
[Operation status at warning occurrence]
Cam auto-generation is not executed.
Outside cam position
"[Cd.613] Cam position calculation: Cam No." is
calculation cam No. range
outside the range of 0 to 256.
[Operation status at warning occurrence]
Cam position calculation is not executed.
Cam position calculation cam
Cam data of the specified cam No. does not exist on
not registered
the cam open area during the cam position calculation.
[Operation status at warning occurrence]
Cam position calculation is not executed.
Outside cam position
"[Cd.615] Cam position calculation: Cam axis length
calculation cam axis length
per cycle" is set to 0 or lower.
per cycle range
[Operation status at warning occurrence]
Cam position calculation is not executed.
search engine
Remedy
• Decrease the number of cam data (number of
cams, cam resolution, and coordinate
number).
• Erase the cam data and rewrite it.
• Set the Input value of coordinate data to 0 or
more.
< X
"
• Set the Input value of coordinate data to "X
n
n+1
X
".
n+1
Delete the cam data read password with a
programming tool.
Delete the cam data write password with a
programming tool.
Set a value within the range of 1 to 256.
Set 1.
• Decrease the number of cam data (number of
cams, cam resolution, and coordinate
number).
• Erase the cam data and rewrite it.
• Decrease the number of cam data (number of
cams, cam resolution, and coordinate
number).
• Erase the cam data and rewrite it.
Set a value within the setting range for the cam
auto-generation.
Review the setting value of the cam auto-
generation data.
Delete the cam data write password with a
programming tool.
Set a value within the range of 0 to 256.
• Specify the cam No. of an existing cam data.
• When writing the cam data from a
programming tool, turn the PLC ready signal
[Y0] from OFF to ON and open the cam data
on the cam open area.
Set a value within the range of 1 to 2147483647.