Siemens SINUMERIK 840C Installation Instructions Manual page 82

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

09.95
Active power (SW 4)
Smoothed current
actual value
Motor temperature
FDD drive service display 2nd screen
FDD
2nd screen
Explanation
Explanation of display fields FDD 2nd screen
Drive status
Feed drive
Set-up mode actual
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
More user manuals on
4.3 Drive service displays for spindle (MSD) and axis (FDD) – as from SW 3)
This display field shows the current active power (drive MD 11011).
This display field shows the smoothed current actual value in percent
(drive MD 1708).
This display field shows the current motor temperature (drive MD 1702).
Select the FDD 2nd screen softkey in the service area for drive MSD/FDD.
Fig. 4.9
The drive service display FDD 2nd screen gives you an overview of the signals
and statuses of the MSD drives and is only a display. The specific drive data (NC,
PLC, Drives) set, determine the contents of the display fields.
This display field describes the ramp-up operating status of the digital drives.
This status is generated in the SERVO during start-up and then changed accor-
dingly in the display (SW 4: drive MD 11008).
Possible data:
0 8
Off
1 8
On (after the drive has returned status signal to
SERVO)
2 8
On-line (communication possible)
3 8
Bootstrap (drive must be rebooted)
4 8
Connected (drive ramp-up completed)
5 8
Ready (drive under closed loop control, Power On)
This display field describes the currently selected FDD drive as selected via
sofkeys drive +/–.
This display field shows the set-up mode status of cyclic status word 1
(drive MD 11002.8)
Possible display range: off or on