6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.7 Axis-specific MD 2 (axial data 2)
1184*-
1196*
Default value
0
This MD has the same meaning as MD 312*, see also functional description of parameter set
switchover.
1200*
Default value
0
With this MD, it is possible to set a time where the contour deviation may exceed that of MD
*
332
without an alarm message "Contour monitoring" being output.
1204*
Default value
1
Active:
The matching of the internal computing precision and the precision of the second measuring
system is carried out in the same way as the settings for the first measuring system
(MD 364*/368*/1116*).
_______
1)
As from SW 2
2)
As from SW 3
3)
As from SW 4
6–162
More user manuals on
Feedforward control factor 4th - 7th parameter set
Lower input limit
+0
Delay for contour monitoring
Lower input limit
0
f: Pulse multiplication EXE/611D/HMS 2nd measuring
Lower input limit
1
After POWER ON
ManualsBase.com
Upper input limit
1 000
Upper input limit
16 000
system
1)
Upper input limit
1)
128
2)
512
©
Siemens AG 1992 All Rights Reserved
04.96
Active on
3)
NC Stop
Units
0.1%
Active in all
channels of
mode group
in STOP
Units
ms
Active on
Power On
Units
6FC5197- AA50
SINUMERIK 840C (IA)