09.95
1507
Input of damping for current setpoint filter 1 (PT2 low-pass). The filter is activated via machine
data MD 1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).
Note:
•
With interpolating axes, the speed setpoint filter must always be parameterized
immediately.
1508
Input of natural frequency for speed setpoint filter 2 (PT2 low-pass). An entry of < 10 Hz as
the natural frequency of the low-pass filter initializes the filter as a proportional element with a
gain of 1 independently of the associated damping. The filter is activated via machine data
MD 1500 (No. speed setpoint filters) and MD 1501 (Type speed setpoint filter).
Note:
With interpolating axes, the speed setpoint filter must always be parameterized immediately.
1509
Input of damping for speed setpoint filter 2 (PT2 low-pass). The filter is activated via machine
data MD 1500 (No. speed setpoint filters) and MD 1501 (Type speed setpoint filter).
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Damping speed setpoint filter 1
Default value
Lower input limit
0.7
Natural frequency speed setpoint filter 2
Default value
Lower input limit
2 000.0
Damping speed setpoint filter 2
Default value
Lower input limit
0.7
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Upper input limit
0.2
5.0
Upper input limit
10.0
8 000.0
Upper input limit
0.2
5.0
6FC5197- AA50
7.3.2 Drive MD (data description)
Active
at once
Units
–
Active
at once
Units
Hz
Active
at once
Units
–
7–127