09.95
2702*
With MD 2702*, the input variables of the torque compensation controller are weighted to
permit a parameterizable torque distribution over both drives according to the respective
moments of inertia.
The standard parameterization of 500 ‰ produces a distribution according to the values in
drive machine data 1725 (normalization torque setpoint interface) for both axes. If a different
distribution is to be used, MD 2702* must be calculated according to the following formula:
MD 2702* =
M
desired
2703*
The P gain of the torque compensation controller is parameterized in % of the ratio drive
maximum speed to nominal torque of the slave drive. The input variable of the torque
compensation controller is the difference in torque between master and slave, the output
variable is a speed setpoint. See also MD 1812* and 523*.
Formula:
Output variable = P gain * control difference
Example:
A torque difference of 10 % of the slave nominal torque and standard parameterization 100
(= 0.01%) produces an output variable of the controller of 0.001 % of the maximum speed of
the slave drive (0.01 % * 10 % = 0.001 %).
2704*
The integral action of the torque compensation controller is parameterized in the integral action
time. The integral action is deactivated if set to the default value 0 because the proportional
action (MD 2703*) already ensures an adequate static distribution of torque.
The additional integral action can produce a better distribution in multi-slave operation. Useful
values are in whole seconds. See also MD 523*.
_______
1)
As from SW 4.4
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Torque distr. torque comp. controller
Default value
Lower input limit
500
M
––––––––––––––––––––––––––––––––––––––––––
M
+ M
desired
desired
slave
is the ideal torque distribution between master and slave.
Torque compensation controller P component
Default value
Lower input limit
100
Torque comp. controller integral action time
Default value
Lower input limit
0
ManualsBase.com
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
Upper input limit
0
984
desired
slave
MD 1725
slave
+
––––––––––––––
master
MD 1725
master
Upper input limit
0
1 000 000
Upper input limit
1 000 000
0
99 999 999 (as from
SW 4.4)
6FC5197- AA50
6.9 MDs for parameter set switchover
Active on
1)
Power On
Units
· 1000 ‰
Active
1)
at once
Units
0.0001%
Active
1)
at once
Units
ms
6–201