6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.6.1 General MD bits (general bits)
NC MD
5005
Default value:
Bit 7 to 5
Bit 4 to 1
Bit 4
Bit 3
Bit 2
Bit 1
NC MD
5006
Default value:
Active:
Bit 6 to 0
Bit 6=0 Input not possible.
Bit 6=1 Input via keyswitch setting 1, 2 and 3 possible.
_______
1)
As from SW 3
6–92
More user manuals on
7
6
5
Keyswitch group
(configurable)
All 0
Configured data blocks can be inhibited via keyswitch by setting these bits
(see also WS 800A description).
The keyswitch can be used to prevent the entry or modification over the NC
operator panel of the following data by setting the corresponding bit(s):
Zero offset (G54 - G57) fine
R parameters angle of rotation zero offset (G54 - G57) coarse
TO wear (parameters P5 to P7)
TO geometry
Bits 2 and 1 are effective only when the standard display for tool offsets
(P0 ÷ 9) is not modified in any way. When configuring tool offsets, the
keyswitch group (bits 5 to 7) for the data fields (P0 to Pxy) must also be
configured via the NC workstation (WS 800A). Bits 1 and 2 can only be set
together or not at all.
Active:
At once
7
6
5
Axis/ spindle
converter
(as from
SW 2)
All 0
Immediately
Entry or modification of the following data over the NC operator panel can be
inhibited via the keylock switch by setting the corresponding NC MD bit(s).
Active:
At once
ManualsBase.com
Bit No.
4
3
2
KEYSWITCH effective for:
Position 1-3
ZO coarse
ZO fine
R param.
TO wear
angle of rot.
Bit No.
4
3
2
KEYSWITCH effective for:
ELG
PP manual
Dry run
program-
input
feedrate
1)
ming via
input
display
©
Siemens AG 1992 All Rights Reserved
09.95
1
0
TO
geometry
1
0
OVER-
STORE
DRF
6FC5197- AA50
SINUMERIK 840C (IA)