7 Drive Machine Data (SIMODRIVE Drive MD)
7.2.2 FDD MD (data description - SW 3)
1002
Default value
100 000
The interrupt clock cycle is used for high-priority monitoring purposes. Note: The input value
for the clock cycle must be a whole multiple of 4 ms (parameterization error).
m x 4000 µs
Note:
The interrupt level must not be exceeded otherwise the drive will be tripped.
1005
Default value
2 048
Input of number of encoder increments per motor revolution of the motor measuring system.
Note:
The indirect measuring system must always be configured for FDD/MSD.
1100
Default value
3 200
The frequency of the sampling triangle in the PWM inverter is defined in this machine data.
The frequency values are set as an MMC function (see attached table).
Value table:
f
PBM
2064.5....
2133.3....
2206.8....
2285.7....
2370.3....
2461.5....
_______
*
A preselection with synchronous sampling period (TPWM) with respect to the controller cycles can be made
via the toggle button.
7–48
More user manuals on
Monitoring cycle
Lower input limit
4 000
m=1, 2, 3, ..., 25
No. encoder marks motor measuring system
Lower input limit
128
Frequency pulse-width modulation
Lower input limit
2 000
in Hz
2000
2560
ManualsBase.com
Upper input limit
100 000
Upper input limit
8 192
Upper input limit
8 000
T
in µs
PBM
500.0*
484.375
468.75
453.125
437.5*
421.875
406.25
390.625
©
Siemens AG 1992 All Rights Reserved
12.93
Active on
Power On
Units
µs
Active on
Power On
Units
Incr/rev
Active on
Power On
Units
Hz
6FC5197- AA50
SINUMERIK 840C (IA)