Siemens SINUMERIK 840C Installation Instructions Manual page 555

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Value table:
Bit 0
Bit 1
Bit 2
Note:
Bit 1 is effective only if signal number 0 is selected in MD 1621 (signal number variable
message function).
The variable message function monitors a freely selectable memory location from address
space X or Y in the data RAM for violation of a threshold specified by the user. A tolerance
band can also be set for this threshold value which is taken into account when the threshold is
scanned for violation. This message is output via operational message with bit 5 and can be
linked to a pickup or dropout delay. The message function is executed in a 4 ms cycle.
Graphic representation
Threshold
Note:
The quantity to be monitored can be selected by specifying either a signal number or a
physical address; the physical address, however, is relevant only for Siemens servicing
purposes.
7–140
More user manuals on
Variable message function
Segment variable message function
Comparison variable message function
Pickup delay time
ManualsBase.com
0 = not active
1 = active
0 = address space X
1 = address space Y
0 = comparison without sign
1 = comparison with sign
Message
Dropout delay time
©
Siemens AG 1992 All Rights Reserved
09.95
Tolerance band
t
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents