Siemens SINUMERIK 840C Installation Instructions Manual page 507

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1119
Default value
0.0
A series reactor is usually required for stable operation of the current controller on high-speed
special asynchronous motors or low-leakage asynchronous motors. In this way the inductance
of the reactor is taken into account in the current model.
Note:
This machine data only applies to main spindle drives.
1120
Default value
10.0
Input of proportional gain of current controller or automatic parameterization (initialization)
through operator action Calulate controller data.
1121
Default value
2000.0
Input of control quantity "Integral-action time of current controller" or automatic
parameterization (initialization) through operator action Calulate controller data.
Note:
Integral arm can be disabled by entering the value T
1124
Default value
0.5
Input of the symmetrizing possibility for the reference model current control loop. This machine
data emulates the calculation deadtime of the current control loop. The emulation is calculated
as approximation of a broken deadtime (see graphic representation MD 1416). This allows the
behaviour of the reference model to be adapted to the controlled system behaviour of the clo-
sed P-controlled current control loop.
Caution:
This machine data is only relevant for Siemens-internal purposes and must not be modified.
7–92
More user manuals on
Inductance of series reactor
Lower input limit
0.0
P-gain current controller
Lower input limit
0.0
Integral-action time current controller
Lower input limit
0.0
Symmetr. ref. model current control loop (up to SW 4)
Lower input limit
0.0
ManualsBase.com
Upper input limit
65.0
Upper input limit
10 000.0
Upper input limit
8 000.0
= 0.
N
Upper input limit
1.0
©
Siemens AG 1992 All Rights Reserved
09.95
Active on
Power On
Units
mH
Active
at once
Units
V/A
Active
at once
Units
µs
Active
at once
Units
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents