Siemens SINUMERIK 840C Installation Instructions Manual page 549

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1521
Default value
100
The description of this machine data is the same as that for machine data MD 1520!
1600
Default value
0000
This machine data allows power on 611D alarms to be concealed. The monitoring function is
activated if the appropriate bit = 0. All 611D monitoring functions are activated as standard.
Value table:
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bits 12-14
Bit 15
7–134
More user manuals on
Band-stop filter natural frequency set speed filter 2
Lower input limit
1
Concealable alarms (Power On)
Lower input limit
0000
Internal error cannot be concealed
Space vector monitoring (as from SW 5 FDD/MSD)
Not assigned
Not assigned
Measuring circuit, motor measuring system
Absolute track monitoring
Not assigned
Not assigned
Zero mark monitoring, motor measuring system
Converter limit frequency too high
Medium frequency measurement, speed too high - not concealable
Medium frequency measured-value memory full - not concealable
Not assigned
Power section temperature monitor
ManualsBase.com
Upper input limit
141
Upper input limit
FFFF
©
Siemens AG 1992 All Rights Reserved
08.96
Active
at once
Units
%
Active
at once
Units
Hex
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents