Siemens SINUMERIK 840C Installation Instructions Manual page 476

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

04.96
1214
Input of 3dB bandwidth for current setpoint filter 2 (band-stop). The filter is activated in
machine data MD 1200 and MD 1201.
Note:
When 0 is entered for the bandwidth, the filter is parameterized as a proportional element with
a gain of 1.
1216
Input of block frequency for current setpoint filter 3 (band-stop). When block frequencies of <
10 Hz are input, the filter is deactivated (proportional element with a gain of 1). The filter is
activated via machine data MD 1200 and MD 1201.
Note:
The maximum block frequency input value is limited by the sampling frequency of the control
(MD 1000) (parameterization error).
MD 1216 < ––––––––––– =
MD 1000 = T
1217
Input of 3dB bandwidth for current setpoint filter 3 (band-stop). The filter is activated in
machine data MD 1200 and MD 1201.
Note:
When 0 is entered for the bandwidth, the filter is parameterized as a proportional element with
a gain of 1.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Bandwidth current setpoint filter 2
Default value
Lower input limit
500
Block frequency current setpoint filter 3
Default value
Lower input limit
3 999.0
1
1
–––––––––
2 x MD 1000
2 x I
62.5 µs
=
sampl.
125.0 µs
Bandwidth current setpoint filter 3
Default value
Lower input limit
100
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Upper input limit
0
1 000
Upper input limit
1
7 999.0
sampl.
8000 Hz
=> MD 1216 <
4000 Hz
Upper input limit
0
1 000
6FC5197- AA50
7.2.2 FDD MD (data description - SW 3)
Active
at once
Units
Hz
Active
at once
Units
Hz
Active
at once
Units
Hz
7–61