Siemens SINUMERIK 840C Installation Instructions Manual page 506

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

07.97
1115
Input of ohmic resistance of the armature winding (phase value) as specified on the motor data
sheet (non-Siemens motor) or automatic parameterization using machine data "Motor code
number" (MD 1102).
Note:
This data is relevant only for FDD drives.
1116
Input of armature rotating-field inductance as specified on the motor data sheet (non-Siemens
motor) or automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for FDD drives.
1117
Input of motor moment of inertia as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102 - in motors
without a holding brake).
* Active on "Power On" until SW < 6
1118
Input of motor zero-speed current as specified on motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102). The above
machine data corresponds to the thermally permissible continuous current at zero motor speed
with an overtemperature of 100 kelvin.
Note:
This data is relevant only for FDD drives.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Default value
Lower input limit
0.0
Default value
Lower input limit
0.0
Default value
Lower input limit
0.0
Default value
Lower input limit
0.0
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Armature resistance
Upper input limit
0.0
20.0
Armature inductance
Upper input limit
0.0
100.0
Motor moment of inertia
Upper input limit
32.0 (SW 5 and
0.0
higher)
Motor zero-speed current
Upper input limit
0.0
500.0
6FC5197- AA50
7.3.2 Drive MD (data description)
Active on
Power On
Units
Active on
Power On
Units
mH
Active
at once*
Units
2
kgm
Active on
Power On
Units
A
7–91