12.93
1409
Input of integral-action time of speed control loop in the lower speed range (N < lower speed
threshold MD 1411). The integral-action times in the lower speed range (MD 1409) and the
upper speed range (MD 1410) are not subject to any mutual restrictions. See machine data
"Adaptation lower speed threshold" (MD 1411) for diagram.
Note:
Setting the integral-action time to zero deactivates the appropriate speed range (suppression
of integral gain and integrator contents = > torque step changes cannot be precluded - see
also Note in MD 1410).
MD 1409 is active over the entire speed range when the "Speed controller adaptation" is
deactivated (MD 1413 = 0).
Caution:
When the adaptation function is active, deactivation of the I-action component for only one
speed range (MD 1409 = 0 and MD 1410 0 or vice versa) should be avoided (to prevent
problem of torque step changes through resetting of the integral value on transition from
adaptation to constant range).
1410
Input of integral-action time of speed control loop in upper speed range (N > upper speed
threshold MD 1412). The integral-action times in the lower speed range (MD 1409) and the
upper speed range (MD 1410) are not subject to any mutual restrictions. See machine data
"Adaptation lower speed threshold" (MD 1411) for diagram.
Note:
Setting the integral-action time to zero deactivates the I-action component for the range which
is greater than the machine data "Adaptation upper speed threshold (MD 1412) (see also Note
in MD 1409).
MD 1410 is not active when the "Speed controller adaptation" is deactivated (MD 1413 = 0).
Caution:
When the adaptation function is active, deactivation of the I-action component for only one
speed range (MD 1409 = 0 and MD 1410 0 or vice versa) should be avoided (to prevent
problem of torque step changes through resetting of the integral value on transition from
adaptation to constant range).
1411
Input of lower speed threshold for adaptation of the speed controller machine data. When the
adaptation function is active, the control machine data MD 1407 and MD 1409 are applied at
speeds n < MD 1411. In the adaptation range MD 1411 < n < MD 1412, linear interpolation
takes place between the two control machine data sets.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Integral-action time speed controller
Default value
Lower input limit
10
Integral-action time upper adaptation speed
Default value
Lower input limit
10
Default value
Lower input limit
0
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Upper input limit
0
500
Upper input limit
0
500
Lower adaptation speed
Upper input limit
0
7 200
6FC5197- AA50
7.2.2 FDD MD (data description - SW 3)
Active
at once
Units
ms
Active
at once
Units
ms
Active
at once
Units
rev/min
7–65