7 Drive Machine Data (SIMODRIVE Drive MD)
7.2.2 FDD MD (data description - SW 3)
1120
Default value
0
Input of proportional gain of current controller or automatic parameterization using machine
data "Motor code number" (MD 1102). It defines the relationship between control voltage
setpoint and control deviation current.
1121
Default value
0
Input of control quantity "Integral-action time of current controller" or automatic
parameterization using machine data "Motor code number" (MD 1102).
Note:
Integral arm can be disabled by entering the value T
1200
Default value
1
Input of number of current setpoint filters. Band-stop and low-pass filters are available; these
are set via the machine data "Configuration current setpoint filter" (MD 1201).
Selection of number of filters:
0
1
2
3
4
Note:
Before a filter is activated, the filter type and the appropriate filter machine data must be input.
7–56
More user manuals on
P-gain current controller
Lower input limit
0
Integral-action time current controller
Lower input limit
0
Selection current setpoint filter
Lower input limit
0
No current setpoint filter activated
Filter 1 activated
Filters 1 and 2 activated
Filters 1, 2 and 3 activated
Filters 1, 2, 3 and 4 activated
ManualsBase.com
Upper input limit
10 000
Upper input limit
10 000
= 0.
N
Upper input limit
4
©
Siemens AG 1992 All Rights Reserved
09.95
Active
at once
Units
V/A
Active
at once
Units
µs
Active
at once
Units
6FC5197- AA50
SINUMERIK 840C (IA)