6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.9.1 MDs for collision monitoring
3816*
Default value
0
3820*
Default value
0
*=Protection zone number
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31
The dimensions of protection zone Sn are entered in the following protection-zone-specific
machine data:
3824*
Default value
0
3828*
Default value
0
3832*
Default value
0
*=Protection zone number
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31
Protection zone dimensions in 2 coordinates not equal to 0:
Two-dimensional monitoring only in the plane described by the coordinates in question (see:
Definition of protection zone planes). In the third coordinate the protection zone is understood
as infinite.
6–206
More user manuals on
Protection zone reference point vector FP1
Y coordinate (as from SW 6)
Lower input limit
0
Protection zone reference point vector FP1
Z coordinate (as from SW 6)
Lower input limit
0
Dimension X coordinate (as from SW 6)
Lower input limit
0
Dimension Y coordinate (as from SW 6)
Lower input limit
0
Dimension Z coordinate (as from SW 6)
Lower input limit
0
ManualsBase.com
Upper input limit
99 999 999
Upper input limit
99 999 999
Upper input limit
99 999 999
Upper input limit
99 999 999
Upper input limit
99 999 999
©
Siemens AG 1992 All Rights Reserved
07.97
POWER ON
Units
MS
POWER ON
Units
MS
POWER ON
Units
MS
POWER ON
Units
MS
POWER ON
Units
MS
6FC5197- AA50