Siemens SINUMERIK 840C Installation Instructions Manual page 479

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.2.2 FDD MD (data description - SW 3)
Note:
Under normal circumstances, shutdown is implemented sequentially on the drive and servo
sides, with variously adjustable timers (NC-MD 156, NC-MD 12240) and, in the event of a
fault, only on the drive side with timer MD 1404.
1405
Default value
110
Input of maximum permissible speed setpoint as a limit value for the speed actual value
monitor. The machine data "Maximum motor speed" (MD 1401) is applied as the reference
value.
1407
Default value
0.3
Input of P-gain of the speed control loop in the lower speed range (n < lower speed threshold
in MD 1411). The P-gain values in the lower speed range (MD 1407) and the upper speed
range (MD 1408) are not subject to any mutual restrictions. See machine data "Adaptation
lower speed threshold" (MD 1411) for diagram.
Note:
Before the P-gain is set to 0, the associated integral-action component (MD 1409) must be
deactivated to maintain controller stability.
MD 1407 is active over the entire speed range when the "Speed controller adaptation" is
deactivated (MD 1413 = 0).
1408
Default value
0.3
Input of P-gain of the speed control loop in the upper speed range (n > upper speed threshold
in MD 1412). The P-gain values in the lower speed range (MD 1407) and the upper speed
range (MD 1408) are not subject to any mutual restrictions. See machine data "Adaptation
lower speed threshold" (MD 1411) for diagram.
Note:
Before the P-gain is set to 0, the associated integral-action component (MD 1410) must be
deactivated to maintain controller stability.
MD 1408 is not active when the "Speed controller adaptation" is deactivated (MD 1413 = 0).
7–64
More user manuals on
Monitoring speed motor
Lower input limit
100
P-gain speed controller
Lower input limit
0
P-gain upper adaptation speed
Lower input limit
0
ManualsBase.com
Upper input limit
110
Upper input limit
100 000
Upper input limit
100 000
©
Siemens AG 1992 All Rights Reserved
12.93
Active
at once
Units
%
Active
at once
Units
Nm/s
-1
Active
at once
Units
Nm/s
-1
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents