Siemens SINUMERIK 840C Installation Instructions Manual page 289

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.6.1 General MD bits (general bits)
NC MD
5020
Default value:
Bit 2
Bit 2 = 1
Bit 2 = 0
NC MD
5021
Neutral position of mixed I/O outputs bit 5 to 0
Bit 5-0=1
Bit 5-0=0
Active:
_______
1)
As from SW 4
6–104
More user manuals on
7
6
5
0
Emergency retraction off (G420) for all channels
Meaning:
Monitoring of the ER sources, specified via MD, OFF for:
-
the channel where the part program is executed
-
all axes of the mode group for ALL channels incl. PLC
-
all spindles of the mode group for ALL channels incl. PLC
G420 X S1 =
Meaning:
Monitoring of the ER sources, specified via MD, OFF for:
-
the X axis for ALL channels incl. PLC
-
the spindle S1 for ALL channels incl. PLC
"G420/G421" from PLC:
Axis-specific:
Spindle-specific:
Monitoring for axes (FA/FS) can also be switched on/off from PLC. If
monitoring is switched off from PLC, it is switched off for all channels.
Emergency retraction off (G420) in current channel
7
6
5
Neutral
position of
outputs for
mode group
1)
6
After Mode Group Reset the output byte of the mixed I/O module is at high
level (24 V).
After Mode Group Reset the output byte of the mixed I/O module is at low
level (0 V).
On Power On
ManualsBase.com
Bit No.
4
3
Emergency
retraction
off (as from
SW4.7
SW 5.2)
DB29
DR K+ 2.5
DB29
DR K+ 26.5
Bit No.
4
3
Neutral
Neutral
Neutral
position of
position of
position of
outputs for
outputs for
outputs for
mode group
mode group
mode group
1)
1)
5
4
3
©
Siemens AG 1992 All Rights Reserved
04.96
2
1
0
DL K+ 2.5
DL K+ 26.5
2
1
0
Neutral
Neutral
position of
position of
outputs for
outputs for
mode group
mode group
1)
1)
1)
2
1
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d