7 Drive Machine Data (SIMODRIVE Drive MD)
7.2.2 FDD MD (data description - SW 3)
Graphic representation:
Adaptation of speed controller machine data by means of characteristic
K
, T
P
MD 1407
Lower speed
range with
constant P gain/
integral-action
time
MD 1409
1412
Default value
0
Input of upper speed threshold for adaptation of the speed controller machine data. When the
adaptation function is active, the control machine data MD 1408 and MD 1410 are applied at
speeds n > MD 1412. In the medium range MD 1411 < n < MD 1412, linear interpolation
takes place between the two control machine data sets.
See machine data "Adaptation lower speed threshold" (MD 1411) for diagram.
1413
Default value
0
This machine data allows adaptation of the speed controller machine data to be controlled as a
function of speed.
Input 0:
Input 1:
7–66
More user manuals on
N
Adaptation
range
MD 1411
Upper adaptation speed
Lower input limit
0
Selection adaption speed controller
Lower input limit
0
The adaptation function is not active. The settings in control machine data
MD 1407 and MD 1409 are applicable over the entire speed range. Control
machine data MD 1408 and MD 1410 are not taken into account.
The adaptation function is active. See machine data MD 1411 and MD 1412 for
description.
ManualsBase.com
MD 1410
Upper speed
range with
constant P gain/
integral-action
time
MD 1408
n
MD 1412
MD 1401
Upper input limit
7 200
Upper input limit
1
©
Siemens AG 1992 All Rights Reserved
04.96
Active
at once
Units
rev/min
Active
at once
Units
6FC5197- AA50
SINUMERIK 840C (IA)