9 Drive Servo Start-Up Application (as from SW 3)
9.2.4 Speed control loop (axis and spindle) – measurement parameters (4 basic settings – as from SW 3)
9.2.4
Overview of
measurement types
Note
D 1st measurement type: Reference frequency response
Meas.
parameters
Notes
Measurement
parameter settings
(see Section "Signal
waveforms
of function generator")
9–16
More user manuals on
Speed control loop (axis and spindle) – measurement parameters
(4 basic settings – as from SW 3)
The types of measurement available depend on the type of drive used. Various
variables can be measured depending on the type of measurement selected.
Type of measurement
Reference frequency response
Interference frequency response (up to
SW 4
Mechanical frequency response n
(as from SW 5)
Setpoint step change
Disturbance step change
If the selected measurement cannot be carried out with the installed drive, the
dialog box 160007 Measurement/drive-type combination not allowed appears
when the Start softkey is selected.
The reference frequency response measurement determines the transient re-
sponse of the speed control loop. The response range should be as wide as pos-
sible and without resonance. It may be necessary to install stop or low-pass
(611D) filters. Particular care must be taken to prevent resonance within the
speed controller limit frequency range.
You can select the menu with the parameters for measuring the speed control
loop with this softkey.
You enter the measurement parameters in the selected display. These parame-
ters are managed internally as configuration data rather than machine data, i.e.
they initialized when the machine runs up. Data can be input in two different
ways:
S
Manual input
S
Input by loading of an existing, complete data set with the aid of file functions
The measurement of the MSD speed control loop frequency response is carried
out with respect to the position control only with SW 3 and therefore makes allo-
wance for system-related transfer times between the position and speed control
loops.
S
Amplitude
This parameter determines the magnitude of the test signal amplitude.
It should not be more than a few (approx. 1–2) motor rpm for the 1st basic
setting (frequency reference response).
S
Offset
The measurement requires a small speed offset of a few motor revolutions
per minute. The offset value must be set higher than the amplitude value.
ManualsBase.com
/Iq
act
act
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
09.95
07.97
Measured quantity Speed
actual value
analog / 611D
611D FDD (SW 3)/
611D (SW 4)
analog / 611D
611D FDD (SW 3)/
611D (SW 4)