Siemens SINUMERIK 840C Installation Instructions Manual page 563

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1650
Default value
0000
Input to select a variety of diagnostic functions in the diagnostic control word.
Caution:
This machine data is relevant only for Siemens-internal purposes and must not be altered.
Value table:
Bit 0
Bit 1
Bit 2
Bits 3-7
Bit 8 (up to
SW 4.4)
Bit 9
Bits 10-15
Notes:
Bit 1 is effective only if signal number 0 is selected in MD 1651 (signal number min/max
memory).
Diagnostic function "Min/max memory"
This function can be used to calculate the value range within which a specific memory
location moves over a prolonged period. The function is executed in the current controller
cycle (fastest cycle) in order to ensure reliable detection of all system quantities.
The quantity to be monitored can be selected through specifying either a signal number or
a physical address (see MD 1651).
The comparison of the value with the maximum and minimum values can be implemented
either with or without sign (bit 2).
Corresponding machine data are as follows:
Diagnosis control (MD 1650, bits 0, 1, 2)
Signal number min/max memory (MD 1651)
Memory location min/max memory (MD 1652)
Minimum value min/max memory (MD 1653)
Maximum value min/max memory (MD 1654)
7–148
More user manuals on
Diagnosis control
Lower input limit
0000
Min/max memory
Segment min/max memory
Comparison with sign
Not assigned
Voltage-controlled V
operation
q
Reserved
Not assigned
ManualsBase.com
Upper input limit
FFFF
0 = not active
1 = active
0 = DSP address name X
1 = DSP address name Y
0 = without sign
1 = with sign
0 = normal operation
1 = V
©
Siemens AG 1992 All Rights Reserved
04.96
Active
at once
Units
Hex
operation active
q
6FC5197- AA50
SINUMERIK 840C (IA)