Siemens SINUMERIK 840C Installation Instructions Manual page 116

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

01.99
09.95
Backup menu tree
1
Restore/backup (first install correct streamer with Item 2/Item3 set streamer type)
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
More user manuals on
1
Install MMC system
When you select menu item 1, new MMC software, SW options (e.g. graphic program-
ming) or software updates are transferred to and installed on the hard disk.
2
Backup system
With the 2nd menu item it is possible to perform a complete system BACKUP, i.e. all
the software (operating system – software, user software and software options) are
transferred from the hard disk to the streamer.
3
Restore system
With the function SYSTEM RESTORE it is possible to transfer a complete previous
BACKUP from the streamer to the hard disk of the MMC CPU. Any existing user data
of the same name are overwritten.
Note:
Other user data are not deleted.
4
Backup user data
With the function BACKUP USER DATA all data in the user branch are transferred
from the hard disk to the streamer.
5
Restore user data
With the function RESTORE USER DATA it is possible to transfer a complete previous
BACKUP copy of the user data from the streamer onto the hard disk of the MMC CPU.
Any existing user data of the same name are overwritten.
Note:
Other user data are not deleted.
6
Free data transfer
1
Uninstall NCK
If you select the function UNINSTALL NCK the entire NCK system software
is erased from the hard disk.
2
Uninstall PG software
If you select the function UNINSTALL PG software, the PG software is
erased.
3
Uninstall the complete system
If you select the function UNINSTALL THE COMPLETE SYSTEM the entire
system software and all user data are erased.
4
Return to previous menu
Note:
Up to SW 4, menu item 6 exists under the designation Setup Streamer. This menu
item is installed for service only and is password-protected. For further information
please refer to the VALITEK MANUAL. This menu item must not be used to select the
type of streamer!
7
Uninstall MMC system
8
Set streamer device
9
Return to main menu
ManualsBase.com
4 MMC Area Diagnosis
4.6 BACKUP with Valitek streamer/PC link
4–53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents