Siemens SINUMERIK 840C Installation Instructions Manual page 211

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.2 General machine data (general data)
335
Default value
100
The minimum reduction factor is entered as a percentage in the general machine data.
The actual path velocity is adapted to the new set path velocity by way of the actual path
acceleration.
336
Default value
0
The velocity increase factor is the value in percent per IP cycle by which the reduction factor
is again increased to 100% after failure to reach the hysteresis threshold of the following axis
velocity.
337
Default value
0
Note:
For further information see description of the function collision monitoring.
338
Default value
0
Note:
For further information see description of the function collision monitoring.
6–26
More user manuals on
Minimum reduction factor (as from SW 6)
Lower input limit
0
Velocity increase factor (as from SW 6)
Lower input limit
0
2nd MCS offset in X coordinates (as from SW 6)
Lower input limit
0
2nd MCS offset in Y coordinates (as from SW 6)
Lower input limit
0
ManualsBase.com
Upper input limit
100
Upper input limit
10 000
Upper input limit
99 999 999
Upper input limit
99 999 999
©
Siemens AG 1992 All Rights Reserved
07.97
Active
at once
Units
%
Active on
at once
Units
0.01·%/T
IPO
POWER ON
Units
MS
POWER ON
Units
MS
6FC5197- AA50