7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
6
Default value
–
Display machine data for the present DC link voltage.
7
Default value
–
Display machine data for the present motor current RMS value.
8
Default value
–
Display machine data for the present reactive power consumption of the motor.
9
Default value
–
Display machine data for the present active power consumption of the motor.
Note:
The sign indicates whether the motor is operating as a motor (+) or a generator (–).
10
Default value
–
Display machine data for the present motor temperature. The temperature is sensed through
temperature resistance measuring devices in the motor stator.
7–2
More user manuals on
DC link voltage
Lower output limit
–
Lower output limit
–
Motor reactive power
Lower output limit
–
Motor active power
Lower output limit
–
Motor temperature
Lower output limit
–
ManualsBase.com
Upper output limit
–
Motor current
Upper output limit
–
Upper output limit
–
Upper output limit
–
Upper output limit
–
©
Siemens AG 1992 All Rights Reserved
12.93
Active
at once
Units
V
Active
at once
Units
A
Active
at once
Units
kVA
Active
at once
Units
kW
Active
at once
Units
°C
6FC5197- AA50
SINUMERIK 840C (IA)