09.95
Motor temperature
Status of binary inputs
(SW 3)
Display of active
functions 1 (SW 3)
Display of active
functions 2 (SW 3)
Drive service display FDD 1st screen
FDD
1st screen
Explanation
Explanation of display fields FDD 1st screen
Drive status
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
More user manuals on
4.3 Drive service displays for spindle (MSD) and axis (FDD) – as from SW 3)
This display field shows the current motor temperature
(SW 3: drive MD 1/SW 4: drive MD 1702).
This display field contains the state of the binary input (drive MD 11).
Possible display range: 0000 – FFFF
This display field contains the current status of active functions 1
(drive MD 254).
Possible display range: 0000 – FFFF
This display field contains the current status of active functions 2
(drive MD 255).
Possible display range: 0000 – FFFF
Press the FDD 1st screen softkey in the service area for drive MSD/FDD.
Fig. 4.8
The drive service display FDD 1st screen gives you an overview of the signals
and statuses of the MSD drives and is only a display. This specific drive data
(NC, PLC, Drives) set, determine the contents of the display fields.
This display field describes the ramp-up and operating status of the digital drives.
This status is generated in the SERVO during start-up and then changed accor-
dingly in the display. (SW 4: drive MD 11008).
Possible data:
0 8
Off
1 8
On (after the drive has returned status signal to SERVO)
2 8
2 8
On-line (communication possible)
3 8
Bootstrap (drive must be rebooted)
4 8
Connected (drive ramp-up completed)
5 8
Ready (drive under closed loop control, Power On)
ManualsBase.com
4 MMC Area Diagnosis
4–17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents