A30640 (F)
SI P2: Fault in the switch-off signal path of the second channel
Remedy
For a higher-level control, the following applies:
● Check the PROFIsafe address in the higher-level control and Motor Module and if required, correct
● Save all parameters (p0977 = 1).
● Carry out a POWER ON for all components.
In general, the following applies:
Upgrade the Motor Module software.
Response for
NO (OFF2)
F
Acknowledg‐
IMMEDIATELY (POWER ON)
ment for F
F30649
SI P2: Internal software error
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Explanation
An internal error in the Safety Integrated software in monitoring channel 2 has occurred.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret as hexadecimal):
Only for internal Siemens troubleshooting.
Remedy
Carry out a POWER ON (power off/on) for all components.
● Re-commission the Safety Integrated function and carry out a POWER ON.
● Upgrade the Motor Module/Hydraulic Module software.
● Contact the Hotline.
● Replace the Motor Module/Hydraulic Module.
F30650
SI P2: Acceptance test required
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment