Data descriptions
9.1 Machine data for SINUMERIK 840D sl
13336
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13337
MD number
Default value 0xFFFF
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13338
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
342
$MN_SAFE_SDP_ASSIGN[0...15]
The selection of the SPL signals $A_OUTSE in the F_SENDDP net data to be transferred can
only be done area for area.
The SPL area is specified in the decimal notation in the format aaa bbb
with aaa = area limit 1, SPL signal $A_OUTSE[aaa]
bbb = area limit 2, SPL signal $A_OUTSE[bbb]
Example:
$MN_SAFE_SDP_ASSIGN[0] = 001 004 or alternatively 004 001. The SPL signals
$A_OUTSE[1] to $A_OUTSE[4] are transferred in the F_SENDDP net data, selected using
MD13337
$MN_SAFE_SDP_FILTER[0].
$MN_SAFE_SDP_FILTER[0...15]
F-net data filter between $A_OUTSE and F_SENDDP
Min. input limit: 0
This MD is used to create an assignment between OUTSE signals and F_SENDDP net data
signals .
The SPL signals selected via MD13336 $MN_SAFE_SDP_ASSIGN are transferred in the
F_SENDDP net data signals, for which a 1 is set in this MD.
Bit x = 1
An SPL signal is transferred at the bit position x of the F_SENDDP net data.
Bit x = 0
No SPL signal is transferred at the bit position x of the F_SENDDP net data.
$MN_SAFE_SDP_ERR_REAC[0...15]
Error response F_SENDDP
Min. input limit: 0
The error response defined here is initiated in the case of a communication error. This value
is valid as long as no other value is entered from the SPL via the system variable
$A_FSDP_ERR_REAC.
Meaning of values:
0 = Alarm 27350 + Stop D/E
1 = Alarm 27350
2 = Alarm 27351 (only display, self-clearing)
3 = no system response
Protection level: 7/2
Protection level: 7/2
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Max. input limit: 0xFFFF
Unit: -
Max. input limit: 3
Unit: -
Safety Integrated