Siemens SINUMERIK 840D sl Function Manual page 334

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data descriptions
9.1 Machine data for SINUMERIK 840D sl
13301
Meaning:
corresponds with ...
Additional reference
13302
MD number
Field index 0: Default value 0
Field index 1: Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
334
$MN_PROFISAFE_OUT_FILTER[0...47]
Filter between $A_OUTSE variables and F-net data
The machine data is used to define in which F-net data bits the relevant $A_OUTSE[n] varia‐
bles are transferred.
Machine data MD10389 $MN_PROFISAFE_OUT_ASSIGN is used to define which
$A_OUTSE[n] variables are transferred into the F-net data bits of the PROFIsafe module.
Example:
Note: For reasons of simplicity, only 16 bits are taken into consideration.
Parameterization:
$MN_PROFISAFE_OUT_FILTER = 1010100101000100
$MN_PROFISAFE_OUT_ASSIGN = 011006
n = 16 11 6 1
|x|x|x|x|x|1|1|1|1|1|1|x|x|x|x|x|
example of a value in the $A_OUTSE variables, x = not relevant
|0|0|0|0|0|0|0|0|0|0|1|1|1|1|1|1|
NCK-internal F-net data image
|1|0|1|0|1|0|0|1|0|1|0|0|0|1|0|0|
$MN_PROFISAFE_OUT_FILTER
|1|0|1|0|1|0|0|1|0|1|0|0|0|1|0|0|
F-net data of the PROFIsafe module
$MN_PROFISAFE_IN_ENABLE_MASK[0...1]
Enable screen form of the connections to PROFIsafe input modules
Min. input limit: 0
min. Input limit: 0
The machine data sets of the PROFIsafe connections to PROFIsafe input modules are ena‐
bled using the enable screen forms.
A machine data set includes the following data:
MD10386 $MN_PROFISAFE_IN_ADDRESS[n]
MD10388$MN_PROFISAFE_IN_ASSIGN[n]
MD13300 $MN_PROFISAFE_IN_FILTER[n]
MD13305 $MN_PROFISAFE_IN_SUBS[n]
Bit n = 0
Machine data set [n] is checked for consistency, however it is not active.
The PROFIsafe connection [n] or the slot [n] is inactive.
Bit n = 1
The machine data set [n] is active.
The PROFIsafe connection [n] or the slot [n] is active.
MD10095 $MN_SAFE_MODE_MASK, bit 1
MD13304 $MN_PROFISAFE_IN_SUBS_ENAB_MASK
Protection level: 7/2
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Max. input limit: FFFFFFFFH
max. Input limit: 0000FFFFH
Unit: -
Safety Integrated

Advertisement

Table of Contents
loading