Siemens SINUMERIK 840D sl Function Manual page 705

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

F01650
SI P1 (CU): Acceptance test required
Remedy
For fault value = 130:
Carry out safety commissioning routine.
For fault value = 1000:
Check the cycle time for the Safety Integrated Basic Functions (r9780) and adapt the set checksum (p9799).
Repeat safety commissioning.
Replace the memory card or the Control Unit.
Activate the safety parameters for the drive involved using STARTER (change settings, copy parameters,
activate settings).
For fault value = 2000:
Check the safety parameters in monitoring channel 1, and adapt the reference checksum (p9799).
For fault value = 2001:
Check the safety parameters in the monitoring channel 2 and adapt the reference checksum (p9899).
For fault value = 2002:
Check whether the safety functions are enabled on both monitoring channels.
For fault value = 2003, 2004, 2005:
Carry out acceptance test and create test certificate. The procedure when carrying out the acceptance test
as well as an example for the acceptance report can be found in the following reference: SINAMICS S120
Safety Integrated Function Manual The fault with fault value 2005 can only be acknowledged when the "STO"
function is deselected.
For fault value = 2010:
Check whether Safe Brake Control is enabled on both monitoring channels (p9602 = p9802).
For fault value = 2020:
Repeat safety commissioning.
Replace the memory card or the Control Unit.
For fault value = 3003:
Carry out function tests for the modified hardware and generate an acceptance report. The procedure when
carrying out the acceptance test as well as an example for the acceptance report can be found in the following
reference: SINAMICS S120 Safety Integrated Function Manual
For fault value = 3005:
Carry out function tests for the modified hardware and generate an acceptance report. The fault with fault
value 3005 can only be acknowledged when the "STO" function is deselected.
For fault value = 9999:
Carry out diagnostics for the other safety-related fault that is present.
F01651
SI P1 (CU): Synchronization, safety time slices unsuccessful
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
11.3 Safety messages for SINAMICS S120