p9825[0...1]
SI HLA shutoff valve wait time (MM)
Sets the wait times for switching on and switching off the shutoff valve.
The valve-specific minimum wait times to evaluate the feedback signal contacts
must be set.
[0] = wait time, switching on
[1] = wait time, switching off
See also: p9625
Notice:
This parameter is overwritten by the copy function of the safety functions integrated
in the drive.
Note:
The set time is internally rounded off to an integer multiple of the monitoring clock
cycle (r9780/r9880).
Unit:
Default value:
μs
[0] 250000.00
[1] 250000.00
p9826
SI HLA shutoff valve feedback signal contacts configuration (MM)
Sets the feedback signal contacts of the shutoff valve to be monitored.
The sensors for the feedback signals of the shutoff valves are connected via X281/
X282.
0: NC contact/NO contact (NC/NO)
1: NC contact / NC contact (NC/NC)
2: NO contact/NO contact (NO/NO)
4: Normally closed contact (NC)
5: Normally open contact (NO)
See also: p9626 caution:
This parameter is overwritten by the copy function of the safety functions integrated
in the drive.
Unit:
Default value:
μs
[0] 250000.00
[1] 250000.00
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Minimum value:
Maximum value:
00.00
2000000.00
Minimum value:
Maximum value:
00.00
2000000.00
Data descriptions
9.2 Parameters for SINAMICS S120
Checksum:
Protection level:
Yes
3
Data type:
Effectiveness:
FloatingPoint32
When exiting the
SI commissioning
mode
Checksum:
Protection level:
Yes
3
Data type:
Effectiveness:
FloatingPoint32
When exiting the
SI commissioning
mode