● Carry out a POWER ON.
This ensures that any errors - i.e. deviations in the data content that may exist between the
NCK and drive - will be detected by the checksum check and crosswise data comparison.
Data must be checked if an error is detected. Cross check errors on the hardware-related
cross checksums (Alarm 27035, message F01680 with ID 2) or Alarm 27032 are normal if
the series commissioning data come from another machine. These errors can be resolved
using the "Confirm SI-HW" softkey (see Chapter "Replacing a motor or encoder
(Page 557)").
If an error no longer occurs, then data has not been changed and is identical to the
acceptance test data. The copy function may be used if data is subsequently altered.
● Carry out random function tests.
The tests are required for acceptance of the new machine.
Software/hardware upgrade
Upgrading software
Please carefully read the instructions in the relevant Update Manual before updating the
software.
Firmware versions
In a system configuration, the firmware versions of the DRIVE-CLiQ components can only
differ from the versions on the CF card, if either
a) The automatic upgrade/downgrade (parameter p7826) is deactivated, or
b) components with a new firmware version can no longer be downgraded to the status of
the version available on the CF card.
Case a) is not permitted when Safety Integrated is used. The automatic upgrade/downgrade
must never be disabled when Safety Integrated is used. (automatic firmware update (p7826)
must be equal to 1)
Case b) is only permissible if this combination has been explicitly approved by the
manufacturer.
10.5

Changing machine data

The user must enter the correct password before he can change the machine data for SI
functions to the system. After data for SI functions has been altered, a new acceptance test
must be carried out on the SI function involved and then recorded and confirmed in the
acceptance report.
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
WARNING
WARNING
Commissioning
10.5 Changing machine data
541