Siemens SINUMERIK 840D sl Function Manual page 684

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
11.2 NCK safety alarms for SINUMERIK 840D sl
27303
F_DP: Number of signals in MD %1[%2] < > MD %3[%4]
Response
Alarm display
NC start disable in this channel
Interface signals are set
Mode group not ready
Channel not ready
NC stop for alarm
Remedy
Correct the specified MD
Program con‐
Switch control system OFF and ON again.
tinuation
27305
F_DP: Parameter MD %1[%2] < > MD %3[%4]
Parameter
%1 = MD name 1
%2 = MD field index for MD name 1
%3 = MD name 2
%4 = MD field index for MD name 2
Explanation
An SPL connection with several SPL couplings (sub-slots) was parameterized, where different values are
entered in the F_DP communication parameters or the connection numbers (%1 and %3).
Note
SPL couplings (sub-slots) of an SPL connection are designated using the same values for:
● F_DP communication parameters
● SPL connection number
The following NCK machine data can be involved:
- MD13334/13344 $MN_SAFE_SDP/RDP_LADDR or
- MD13335/13345 $MN_SAFE_SDP/RDP_TIMEOUT or
- MD13333/13343 $MN_SAFE_SDP/RDP_CONNECTION_NR
- MD13338/13348 $MN_SAFE_SDP/RDP_ERR_REAC
- MD13349 $MN_SAFE_RDP_SUBS
Response
Alarm display
NC start disable in this channel
Interface signals are set
Mode group not ready
Channel not ready
Remedy
Correct the specified MD
Program con‐
Switch control system OFF and ON again.
tinuation
27306
F_DP: Max. number of active SPL connections (%1) for (%2) exceeded
Parameter
%1 = maximum number of possible SPL connections
%2 = communication type
Explanation
In the active parameterizing data sets for the specified communication type (F_SENDDP/FRECVDP), more
than the permissible number of SPL connections, designated using different IDs (MD13331/13341
$MN_SAFE_SDP/RDP_ID), were parameterized.
684
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Safety Integrated

Advertisement

Table of Contents
loading

Table of Contents