13346
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13347
MD number
Default value 0xFFFF
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13348
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MN_SAFE_RDP_ASSIGN[0...15]
Input assignment F_RECVDP net data to $A_INSE
Min. input limit: 0
The selection of the SPL signals $A_INSE to be supplied from the F_RECVDP net data can
only be done area for area.
The SPL area is specified in the decimal notation in the format aaa bbb
with aaa = area limit 1, SPL signal $A_INSE[aaa]
bbb = area limit 2, SPL signal $A_INSE[bbb]
Example:
$MN_SAFE_RDP_ASSIGN[0] = 001 004 or alternatively 004 001:
The F_RECVDP net data, selected using MD13347 F_RDP_FILTER[0] are transferred in the
SPL signals $A_INSE[1] to $A_INSE[4].
$MN_SAFE_RDP_FILTER[0...15]
F-net data filter between F_RECVDP and $A_INSE
Min. input limit: 0x0
This MD is used to create an assignment between F_RECVDP net data signals and INSE
signals.
The F_RECVDP net data signals, for which a 1 is set in this MD, are transferred in the SPL
signals selected using MD13346 $MN_SAFE_RDP_ASSIGN.
Bit x = 1
The F_RECVDP net data signal of bit position x is transferred as SPL signal.
Bit x = 0
The F_RECVDP net data signal of bit position x is not transferred as SPL signal.
$MN_SAFE_RDP_ERR_REAC[0...15]
Error response F_RECVDP
Min. input limit: 0
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/2
Protection level: 7/2
Protection level: 7/2
Data descriptions
Max. input limit: 192192
Unit: -
Max. input limit: 0xFFFF
Unit: -
Max. input limit: 3
Unit: -