Checking The Synchronization Position - ABB IRB 6650S Series Product Manual

Table of Contents

Advertisement

5 Calibration

5.7 Checking the synchronization position

5.7 Checking the synchronization position
Introduction
Check the synchronization position of the robot before beginning any programming
of the robot system. This may be done:
Using a MoveAbsJ instruction on the TPU, S4Cplus
Use this procedure to create a program that runs all the robot axes to their
synchronization position.
1
2
3
Using a MoveAbsJ instruction
Use this procedure to create a program that runs all the robot axes to their
synchronization position.
1
2
3
4
5
6
Continues on next page
414
Using a MoveAbsJ instruction with argument zero on all axes.
Using the Jogging window on the FlexPendant.
Action
Create the following program:
MoveAbsJ [[0,0,0,0,0,0], [9E9,
9E9,9E9,9E9,9E9,9E9]]
\NoEOffs, v1000, z50, Tool0
Run the program in manual mode.
Check that the synchronization marks for the axes
align correctly. If they do not, update the revolution
counters.
Action
On ABB menu tap Program editor.
Create a new program.
Use MoveAbsJ in the Motion&Proc menu.
Create the following program:
MoveAbsJ [[0,0,0,0,0,0],
[9E9,9E9,9E9,9E9,9E9,9E9]]
\NoEOffs, v1000, fine, tool0
Run the program in manual mode.
Check that the synchronization marks for the axes
align correctly. If they do not, update the revolu-
tion counters.
© Copyright 2004-2018 ABB. All rights reserved.
Note
See
Synchronization marks and
synchronization position for axes
on page 394
and
Updating revolution
counters on page
396.
Note
See
Synchronization marks and
synchronization position for axes on
page 394
and
Updating revolution
counters on page
396.
Product manual - IRB 6650S
3HAC020993-001 Revision: Z

Advertisement

Table of Contents
loading

Table of Contents