Inspecting, mechanical stops
Use this procedure to inspect the additional mechanical stops.
1
2
3
4
Product manual - IRB 6650S
3HAC020993-001 Revision: Z
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
Make sure no additional stops are damaged.
Make sure the stops are properly attached.
Correct tightening torque, additional mechanical
stops:
Axis 1 = 120 Nm.
Axes 2 and 3 = 115 Nm
If any damage is detected, the mechanical stops must
be replaced.
Correct attachment screws:
Axis 1: M16 x 35, quality 12.9.
Axis 2: M16 x 50
Axis 3: M16 x 60
© Copyright 2004-2018 ABB. All rights reserved.