Switchgear; Time Settings - GE F650 Instruction Manual

Digital bay controller
Hide thumbs Also See for F650:
Table of Contents

Advertisement

5 SETTINGS
2
(KI)
t PHASE A
2
(KI)
t PHASE B
2
(KI)
t PHASE C
BKR OPENING TIME
BKR CLOSING TIME
There is the possibility to enable or disable the generation of internal signals for the different elements (protection, control,
inputs and outputs, switchgear) available in the device.
The configuration of snapshot events for each switchgear (enable or disable) can be selected at Setpoint > System Setup
> Switchgear.
Table 5–26: SWITCHGEAR SETTINGS
SETPOINT > SYSTEM SETUP > SWITCHGEAR
SETTING DESCRIPTION
Snapshot Event generation for switchgear #1
Snapshot Event generation for switchgear #2
Snapshot Event generation for switchgear #3
Snapshot Event generation for switchgear #4
Snapshot Event generation for switchgear #5
Snapshot Event generation for switchgear #6
Snapshot Event generation for switchgear #7
Snapshot Event generation for switchgear #8
Snapshot Event generation for switchgear #9
Snapshot Event generation for switchgear #10
Snapshot Event generation for switchgear #11
Snapshot Event generation for switchgear #12
Snapshot Event generation for switchgear #13
Snapshot Event generation for switchgear #14
Snapshot Event generation for switchgear #15
Snapshot Event generation for switchgear #16
The date and time can be synchronized a known time using the SNTP protocol or IRIG-B protocol (when it provides UTC
Time) and the TIME SETTINGS allow setting the date and time provided by these protocols to the proper local time on the
Real Time Clock.
When there is no SNTP protocol enabled or IRIG-B protocol is not set to UTC Time, the TIME SETTINGS are not used in
the Real Time Clock but are still used to calculate the UTC Time (i.e., for the IEC61850 protocol), but its behavior is not
assumed correct in several critical hour changes because of Daylight Savings Time getting effective. In these configuration
cases, it is recommended to disable Daylight Savings Time.
Table 5–27: TIME SETTINGS
GEK-106310AB
2
Accumulated (KI)
t value for phase A ((KI)
2
Accumulated (KI)
t value for phase B ((KI)
2
Accumulated (KI)
t value for phase C ((KI)
Maximum breaker Opening time. This signal is configured at Setpoint > Relay Configuration
>Switchgear in the number of switchgear corresponding to the breaker selection
Maximum breaker Closing time. This signal is configured at Setpoint > Relay Configuration
>Switchgear in the number of switchgear corresponding to the breaker selection
NAME
Snapshot Events SWGR 1
Snapshot Events SWGR 2
Snapshot Events SWGR 3
Snapshot Events SWGR 4
Snapshot Events SWGR 5
Snapshot Events SWGR 6
Snapshot Events SWGR 7
Snapshot Events SWGR 8
Snapshot Events SWGR 9
Snapshot Events SWGR 10
Snapshot Events SWGR 11
Snapshot Events SWGR 12
Snapshot Events SWGR 13
Snapshot Events SWGR 14
Snapshot Events SWGR 15
Snapshot Events SWGR 16
F650 Digital Bay Controller
2
t Counter for Phase A)
2
t Counter for Phase B)
2
t Counter for Phase C)
DEFAULT
STEP RANGE
VALUE
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
DISABLED
N/A
5.3 SYSTEM SETUP

5.3.4 SWITCHGEAR

[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]
[DISABLED – ENABLED]

5.3.5 TIME SETTINGS