Test The Facility Loopback Circuit; Perform A Terminal Loopback On An Intermediate-Node Oc-N Port; Create The Terminal Loopback On An Intermediate-Node Oc-N Port - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
General Troubleshooting

Test the Facility Loopback Circuit

If the test set is not already sending traffic, send test traffic on the loopback circuit.
Step 1
Examine the traffic received by the test set. Look for errors or any other signal information that the test
Step 2
set is capable of indicating.
If the test set indicates a good circuit, no further testing is necessary with the facility loopback:
Clear the facility loopback:
Step 3
a.
b.
c.
d.
e.
Clear the facility loopback circuit:
Step 4
a.
b.
c.
d.
If the test set indicates a faulty circuit, the problem might be a faulty OC-N port. Continue with the
Step 5
"1.3.5 Perform a Terminal Loopback on an Intermediate-Node OC-N Port" procedure on page

1.3.5 Perform a Terminal Loopback on an Intermediate-Node OC-N Port

The terminal loopback test is performed on the node destination port in the circuit, in this example, the
destination OC-N port in the intermediate node. First, create a bidirectional circuit that starts on the node
source OC-N port and loops back on the node destination OC-N port. Then continue with the terminal
loopback test. Completing a successful terminal loopback to a node destination OC-N port verifies that
the circuit is good up to the destination OC-N port.
Caution
Performing a loopback on an in-service circuit is service-affecting.

Create the Terminal Loopback on an Intermediate-Node OC-N Port

Connect an optical test set to the port you are testing:
Step 1
a.
b.
c.
78-17235-01
Click the Maintenance > Optical > Loopback > Port tabs.
Choose None from the Loopback Type column for the port being tested.
Choose the appropriate state (IS,AINS; OOS,DSBLD; or OOS,MT) from the Admin State column
for the port being tested.
Click Apply.
Click Yes in the confirmation dialog box.
Click the Circuits tab.
Choose the loopback circuit being tested.
Click Delete.
Click Yes in the Delete Circuits dialog box.
If you just completed the
"1.3.4 Perform a Facility Loopback on an Intermediate-Node OC-N Port"
procedure on page
1-17, leave the optical test set connected to the OC-N port in the source node.
If you are starting the current procedure without the optical test set connected to the OC-N port, use
appropriate cabling to attach the Tx and Rx terminals of the optical test set to the port you are
testing.
Adjust the test set accordingly.
1.3.5 Perform a Terminal Loopback on an Intermediate-Node OC-N Port
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-19.
1-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents