Alarm List By Logical Object Type; Table 1-8 Ons 15310-Cl And Ons 15310-Ma Alarm List By Logical Object As Shown In Alarm Profile - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.4 Alarm List by Logical Object Type

Table 1-7
Type
STSMON
STSTRM
VCG
VT-MON
VT-TERM
1.4 Alarm List by Logical Object Type
Table 1-8
are given in the system alarm profile. The list entries are organized by logical object name and then by
alarm or condition name. Where appropriate, the alarm entries also contain troubleshooting procedures.
The list is given here exactly as it is shown in CTC, and in some cases does not follow alphabetical order.
Note
Table 1-8
ONS 15310-CL and ONS 15310-MA Alarm List by Logical Object as Shown in Alarm Profile
BITS: AIS (NR)
BITS: LOF (MN)
BITS: LOS (MN)
BITS: SSM-DUS (NA)
BITS: SSM-FAIL (MN)
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-10
Alarm Logical Object Type Definitions (continued)
Definition
STS alarm detection at the monitor point (upstream from the cross-connect).
The network element reports alarms or conditions on ingress ports of the
Note
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of STSMON, if
available, should be changed to the same severity as the customized
severity for a specific STS alarm.
STS alarm detection at termination (downstream from the cross-connect).
Note
The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of STSTRM, if
available, should be changed to the same severity as the customized
severity for a specific STS alarm.
Virtual concatenation group.
VT1 alarm detection at the monitor point (upstream from the cross-connect).
The network element reports alarms or conditions on ingress ports of the
Note
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of VT-MON, if
available, should be changed to the same severity as the customized
severity for a specific VT alarm.
VT1 alarm detection at termination (downstream from the cross-connect).
The network element reports alarms or conditions on ingress ports of the
Note
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of VT-TERM, if
available, should be changed to the same severity as the customized
severity for a specific VT alarm.
lists all ONS 15310-CL and ONS 15310-MA Release 7.0 alarms and logical objects as they
EQPT: SFTWDOWN (MN)
EQPT: SW-MISMATCH (NA)
EQPT: SWMTXMOD-PROT (CR)
EQPT: SWMTXMOD-WORK (CR)
EQPT: WKSWPR (NA)
Chapter 1
Alarm Troubleshooting
OCN: SSM-STU (NA)
OCN: STS-SQUELCH-L (NA)
OCN: SYNC-FREQ (NA)
OCN: TIM (CR)
OCN: TIM-MON (MN)
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents