Clear The Eoc-L Alarm; Eqpt; Clear The Eqpt Alarm - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.7.58 EQPT

Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Warning
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100 mm could pose an eye hazard. Statement 1056
Use of controls, adjustments, or performing procedures other than those specified could result in
Warning
hazardous radiation exposure. Statement 1057
If a circuit shows an incomplete state when the EOC or EOC-L alarm is raised, it occurs when the logical
Note
circuit is in place. The circuit is able to carry traffic when the DCC termination issue is resolved. You
do not need to delete the circuit when troubleshooting this alarm.

Clear the EOC-L Alarm

Complete the
Step 1
If the alarm has not cleared, call Cisco TAC (1 800 553-2447).
Step 2
1.7.58 EQPT
An Equipment Failure alarm indicates that a hardware failure has occurred on the reporting card. If the
EQPT alarm occurs with a BKUPMEMP alarm, refer to the
BKUPMEMP procedure also clears the EQPT alarm.

Clear the EQPT Alarm

If traffic is active on the alarmed port, you might need to switch traffic away from it. See the
Step 1
"1.10.1 Protection Switching, Lock Initiation, and Clearing" section on page 1-148
traffic-switching procedures.
Complete the
Step 2
the reporting card.
Caution
Avoid soft-resetting multiple ONS 15310-MA cards at one time; doing so might cause an unexpected
traffic hit.
For the LED behavior, see the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-52
"Clear the EOC Alarm" procedure on page
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
DWDM Logical Object: PPM
"Soft- or Hard-Reset an Ethernet or Electrical Card in CTC" procedure on page 1-154
"1.9.2 Typical Card LED Activity During Reset" section on page
Chapter 1
Alarm Troubleshooting
1-50.
"BKUPMEMP" alarm on page
for commonly used
1-33. The
for
1-148.
78-17235-01