1.7.113 INC-ISD

1.7.113 INC-ISD
The DS-3 Idle condition indicates that the DS-3 port is receiving an idle signal from a 15310-CL-CTX,
ONS 15310-MA DS1-28/DS3-EC1-3, or ONS 15310-MA DS1-84/DS3-EC1-3 DS-1 port, meaning that
the payload of the signal contains a repeating pattern of bits. The INC-ISD condition occurs when the
transmitting port has an OOS-MA,MT service state. It is resolved when the OOS-MA,MT state ends.
INC-ISD is a condition and not an alarm. It is for information only and does not require troubleshooting.
Note

1.7.114 INCOMPATIBLE-SEND-PDIP

The Incompatible Software alarm is raised when CTC'S send PDIP provisioning differs from host node's
provisioning.

Clear the INCOMPATIBLE-SEND-PDIP Alarm

Reconfigure CTC's send PDI-P alarm capability to align with the host node settings.
Step 1
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1-800-553-2447).

1.7.115 INCOMPATIBLE-SW

The Incompatible Software alarm is raised when CTC cannot connect to the NE due to incompatible
versions of software between CTC and the NE. The alarm is cleared by restarting CTC in order to
redownload the CTC jar files from the NE.

Clear the INCOMPATIBLE-SW Alarm

Step 1
Restart the CTC application.
Step 2
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-78
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: DS3
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: SYSTEM
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET SONET Logical Object: NE
Chapter 1
Alarm Troubleshooting
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents